Plants, buildings, utilities & facilities

Industrial Division

Electrical, instrumentation, and automation for production lines, utilities, and WWTPs (IPAL), from machines that stop without warning to new panel and system projects.

WWTP (IPAL) · BioTRIAS

Wastewater treatment plants (IPAL) for buildings and plants

We design, install, and automate wastewater treatment plants so the treated water meets environmental standards, complete with control panels and real-time parameter monitoring.

  1. 1Screening & grit chamber
  2. 2Equalisation tank
  3. 3Anaerobic reactor
  4. 4Aerobic reactor
  5. 5Clarifier
  6. 6Media filter
  7. 7Disinfection
Infographic: anatomy and working principle of building and plant WWTPs by TRIAS Group Enlarge infographic
Installing a BioTRIAS wastewater tank on site
BioTRIAS tank installation on site
  • Design and installation of BioTRIAS tanks for buildings and plants, sized to your requirements.
  • PLC/HMI control panels for blowers, dosing pumps, and recirculation pumps.
  • Real-time IoT monitoring of effluent parameters (pH, COD, TSS, ammonia, flow).
  • Technology matched to the wastewater: MBR, SBR, MBBR, or compact STP.
Discuss your WWTP needs

Running repair & troubleshooting

Common fault points and how we resolve them

Select a point to see the typical symptoms, our diagnostic approach, and the solution we apply to systems that must stay in operation.

250.0 WWTP

01 / 08

Generator set & power quality

Typical symptoms
Generators fail to synchronise, capacitors fail early, or kVARh penalties appear on the power bill.
Diagnostic approach
A power quality study, harmonic measurements, and inspection of the generator synchronising modules.
Solution
Installation or repair of capacitor banks and harmonic filters, and set-up of the synchronising modules.

Project references

  • Hotel Indonesia Kempinski (ComAp)
Discuss this issue

02 / 08

Distribution panels & MCC

Typical symptoms
MCBs or ACBs trip frequently, panels run hot, or motors will not start.
Diagnostic approach
Thermography, current and load measurements, and inspection of contactors, relays, and terminations.
Solution
Repair or replacement of components, load rebalancing, or a new panel built in our workshop.

Project references

  • PT Nalco / Ecolab Indonesia
  • PT Mesin Isuzu Indonesia
  • PT Amerta Indah Otsuka
Discuss this issue

03 / 08

Inverters & servo drives

Typical symptoms
Inverter faults or overcurrent, servo alarms, and machines stopping unexpectedly.
Diagnostic approach
Reading alarm codes and inspecting power modules, capacitors, encoders, and motors.
Solution
Component-level board repair for all major brands, load-tested in our workshop before reinstallation.

Project references

  • PT Megasari Makmur (Panasonic)
  • PT Agri Lestari Nusantara
  • PT Yasulor Indonesia
Discuss this issue

04 / 08

Production machine PLC & HMI

Typical symptoms
The HMI is blank or frozen, the program is lost, or the machine will not enter automatic mode.
Diagnostic approach
Inspection of the power supply, communication, I/O, and program backups.
Solution
PLC or HMI repair, program recovery or correction, and handover of a program backup.

Project references

  • PT Khong Guan Biscuit Factory Indonesia
  • PT Inasentra Uni Satya (Schneider)
  • PT Pelita Samudra Shipping (Siemens)
Discuss this issue

05 / 08

Packaging & filling machines

Typical symptoms
High reject rates, inconsistent sensors, or machine motions out of sync.
Diagnostic approach
Inspection of sensors, timing, servos, and program logic.
Solution
Repair, re-tuning, or modification until the machine runs consistently.

Project references

  • PT Reckitt Benckiser
  • PT Akasha Wira International
  • PT Agricon
Discuss this issue

06 / 08

Scales & weighing tanks

Typical symptoms
Weighing results drift or readings fail to settle.
Diagnostic approach
Inspection of load cells, junction box, indicator, and mechanical mounts.
Solution
Repair or replacement of load cells, followed by calibration.

Project references

  • PT Diamond Cold Storage
  • PT Singgar Mulia
  • PT UTC Aerospace Systems
Discuss this issue

07 / 08

Utilities: boilers, chillers & compressors

Typical symptoms
Chillers or compressors trip, boilers fail to run automatically, or energy consumption rises.
Diagnostic approach
Inspection of the control panel, sensors, protection, and alarm history.
Solution
Control repair, re-automation, and energy monitoring.

Project references

  • PT Diamond Cold Storage (Bitzer)
  • PT Summarecon Agung Tbk
  • PT Honda Prospect Motor
Discuss this issue

08 / 08

WWTP (IPAL)

Typical symptoms
Aeration blowers trip, dosing pumps run out of step, or effluent parameters (pH, COD, TSS) exceed permitted limits.
Diagnostic approach
Inspection of the PLC/HMI control panel, pH and DO sensors, pumps, blowers, and process data.
Solution
Panel and sensor repair, blower and pump automation, and real-time IoT monitoring of effluent parameters.

Project references

  • PT Yasulor Indonesia (HMI WWTP)
  • BioTRIAS
Discuss this issue

Industrial Division projects

Select a card to view the scope of work.

See alsoMarine DivisionPassenger ships, tankers, cargo ships, tugs & offshore

Need technical support?

Send a photo of the equipment or a brief summary of your needs. Our engineers will respond with recommended next steps.